Description:
| Model |
DF-96B |
DF-96C |
DF-96D |
| Working Voltage |
220V |
220V |
380V |
| Load Current |
10A |
16A |
16A |
| Installation method |
guide |
guide |
guide |
| Size(mm) |
126x88x51 |
126x88x51 |
126x88x51 |
Wiring Method1. Direct control mode wiring:
The controlled appliance is single-phase power supply, and the power consumption does not exceed the rated capacity of the switch (resistive load 10A, inductive load 5A can be directly controlled, the wiring method is shown in Figure 1.)
2. Single-phase expansion mode wiring
The controlled appliance is single-phase power supply, but the power consumption exceeds the rated capacity of the switch, then an AC contactor with a capacity exceeding the power consumption of the appliance is needed to expand. The wiring is shown in Figure 2.
3. Wiring of three-phase working mode
The controlled appliance is a three-phase power supply and requires an external three-phase AC contactor.
The wiring diagram of the control contactor is AC220V, 50Hz wiring as shown in Figure 3.