{"product_id":"3pcs-dc-12v-5a-overcurrent-protection-sensor-module-ac-current-detection-relay-module-switch-output_1361910","title":"3Pcs DC 12V 5A Overcurrent Protection Sensor Module AC Current Detection Relay Module Switch Output","description":"\u003cdiv style=\"font-size: 13.3333px; font-variant-numeric: normal; font-variant-east-asian: normal; line-height: normal; widows: 1;\"\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eLC 5A Over-current protection Sensor module uses current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current. Users can use the relay COM, NC, NO three ports to control the external circuit on and off, in order to achieve over-current protection.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-Current detection resolution can change the parameter of resistance parameters;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-Output over-current switching signal output;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-Over-current signal setting critical point adjustable,\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating voltage: DC12V\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating current: \u0026lt;20MA\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating frequency range: 20Hz ~ 400Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOutput mode: switch signal output\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMaximum detection wire diameter: 5.2mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMounting hole: hole diameter is 3mm, hole distance is 52.5mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating environment: -40 ℃ ~ +85 ℃\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eThe current detection range :AC0.3A-5A\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eBoard size: 38 * 44mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eThe Board Description:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eVCC: Operating voltage positive;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eGND :Operating voltage negative;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eNO: Normally open, the relay pulls before the NO and COM disconnect, short-circuit after the suction;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eCOM: common, relay common interface;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eNC: Normally closed, the relay before the NC and COM short-circuit, pull off after.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eUsing Instructions: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eBy setting the potentiometer to set the overcurrent protection point, the clockwise adjustment reduces the detection current.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eAs bellows:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. Measured the wire through the current transformer , connect VCC and GND to DC12V power supply;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. Adjust the potentiometer, when you hear the sound of the relay pull (can be measured with a multimeter COM and NO whether was turned on, if connected to the relay means activated), then reduce or cut off the current flowing  that through the tested wire , if the relay release at this time that over-current protection point has been identified (available to multimeter COM and NC measurement whether is connected, if connected to the relay means been released);\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. When reduce or cut off the current flowing through the wire , the relay is not released, will still need to continue to adjust the potentiometer to find the over-current protection point.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"font-size: 13.3333px; font-variant-numeric: normal; font-variant-east-asian: normal; line-height: normal; widows: 1;\"\u003e \u003c\/div\u003e\u003cdiv style=\"font-size: 13.3333px; font-variant-numeric: normal; font-variant-east-asian: normal; line-height: normal; widows: 1;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cdiv style=\"font-size: 13.3333px;\"\u003e\u003cspan style=\"font-size: 14px;\"\u003e3 x 5A 12V Relay Module\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e\u003cbr style=\"font-size: 13.3333px;\"\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":31968940589194,"sku":"U2I-BG-1361910","price":3969.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/c0bdae5f-2b19-4cdd-85b0-86e0fd1ee55b.jpg?v=1580171476","url":"https:\/\/shop2india.com\/products\/3pcs-dc-12v-5a-overcurrent-protection-sensor-module-ac-current-detection-relay-module-switch-output_1361910","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}