{"product_id":"3pcs-dc-5v-to-60v-real-time-relay-module-clock-synchronization-timer-module-time-control-delay_1334628","title":"3pcs DC 5V To 60V Real-time Relay Module Clock Synchronization Timer Module Time Control Delay","description":"\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eParameter:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eVoltage supply: DC 5V-60V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eWeight: 34g\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFeatures: buzzer alarm\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eFunctional mode description:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOPE: relay closure time\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eCLE: relay off time\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eTime period: PE-1 to PE-5, 5 time periods\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e\"----\": function blocking\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP-1:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003edaily OPE relay closed \/ output pulse CLE relay open \/ output pulse\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP-2:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eon the day OPE relay closed \/ output pulse CLE relay off \/ output pulse\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP-3:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eday of the month: OPE relay closed \/ output pulse CLE relay open \/ output pulse\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP-4:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003emonths to months: OPE relay is closed \/ output pulse CLE relay is open \/ output pulse\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eP-5:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003ehours of the month to the beginning of the few days of the month, to the end of the several points: OPE relay is closed \/ output pulse CLE relay is open \/ output pulse\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eHow to set the time:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn the time running interface, press and hold DOWN:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. The system flashes to display “YEA” and then enters the time setting interface. At this time, the two digits after “Year” flash and are adjusted by DOWN and UP (long press is supported);\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. Short press the SET system flashing display \"dAE\" after entering the \"month \/ day\" setting interface, this time \"monthly\" keeps flashing, through DOWN, UP adjustment (support long press);\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. Press SET shortly. At this time, “day” flashes. Adjust by DOWN and UP (support long press);\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e4. Press SET shortly, and the system flashes to show ‘HOU’ and then enters “Time \/ Minute” setting interface. At this time, “time” flashes continuously, and is adjusted by DOWN and UP (long press is supported);\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e5. Short press SET, at this time \"minute\" flashes, through DOWN, UP adjustment (support long press) short press SET at this time, repeat step 1;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e6. After long pressing SET to let go, it will modify the time according to the set parameters and exit the time setting interface.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eHow to set parameters:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOn the time running interface, press and hold the SET button for 2 seconds to release the hand and the system enters the parameter setting interface:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 1:\u003cbr\u003eselect the time period: PE-1~PE-5 by a short press UP, DOWN key to select;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 2:\u003cbr\u003eselect the mode: \"----\" P-1~P-5 (that is, set this time period to the corresponding mode) by short press UP, DOWN key to select; (\"---- ” indicates that this period of time is masked)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 3:\u003cbr\u003eafter the mode selection is completed, press SET shortly to enter the time setting interface. In the time setting interface, press SET to switch parameters, “OPE” start time, “CLE” end time, “dAE” date information;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 4:\u003cbr\u003eexit the setting after the parameter is set. Press and hold the SET button for 2 seconds to release the hand. Check whether the parameter setting is legal. Save the parameter if legal, and return to the time operation interface. If the parameter is incorrect, the “ERR” alert is displayed. (stop time \/ date ≤ start time \/ date error message) Return to parameter setting interface again.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eStop time \/ date (CLE) \u0026gt; start time \/ date (OPE)\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eAdditional features:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eAny time period can be set individually.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn the specific parameter setting interface (after the second step), press STOP briefly to switch the output mode:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOUT1: start point on relay, end point off relay\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOUT2: output 1S pulse at time\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIn the specific parameter setting interface (after the second step), press STOP to switch the ring mode:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003ebLL0: ringing prohibited\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003ebLL1: ring enable\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eNote: when you ring, press any key to stop the bell\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003eSleep mode:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. C-P sleep mode: no operation within five minutes, the digital tube automatically shuts off the display and the program runs normally;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. O-d normal mode: the digital tube is always on display;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3. In the time display interface, press and hold the STOP button for 2 seconds and then release it to switch between C-P and O-d states. The current state will blink, and then return to the main interface.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 16px;\"\u003ePackage included:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e3 X Clock synchronization timer relay module\u003c\/span\u003e\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":31968945438858,"sku":"U2I-BG-1334628","price":4402.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/a3f23773-e0f8-41e8-8034-49d98f417d01.jpg?v=1580171540","url":"https:\/\/shop2india.com\/products\/3pcs-dc-5v-to-60v-real-time-relay-module-clock-synchronization-timer-module-time-control-delay_1334628","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}