DC 12V 2.5W Car Solenoid Air Valve 5 Port 2 Position
Save 0
SKU: U2I-BG-928616
Share this product
Description
DC 12V 2.5W Solenoid Air Valve 5port 2position BSP 4V110-06 Pilot-operated Type
Specifications:
Material: Alloy Steel Color: Like the picture show Quantity: 1 pc Size(LxWxH): 9.4cm x 1.8cm x2.6cm / 3.7" x 0.7" x 1.02" Wire length: 33cm / 12.99" Packing box dimension(LxWxH): 10cm x 5.6cm x 2cm Model: 4V110-06 Positions: 5 ports/2 positions Motion Pattern: Pilot-operated Type Wiring Form: screw thread type Voltage: DC 12V Allowable Voltage Fluctuation: ±10% of Rated Voltage Power Consumption: AC:2.5VA / DC2.5W Operating Tempe: -5 to + 50°C / 41-122°F Effective Section Area: 12mm² (CV=0.67) Port Size: Air Inlet=Air Outlet=Exhaust=1/8"BSP Working Media/Fluld: 40 Micron Filtered Air Operating Pressure: 0.15-0.8 MPa / 22-116 PSI Max. Pressure Resistance: 1.2MPa / 174 PSI Insulation and Protection Class: F Class / IP65 Highest Action Frequency: 5/s Shortest Excitation Time: 0.05 second
Feature: Pilot-operated Type: external and internal optional Strut structure, good sealing, responsive Three-position solenoid valve has three central features to choose from Double two position solenoid valve with memory function The hole using a special process, friction resistance, low starting pressure, long life Can be integrated with the base valve, saving installation space Has a manual device, installation and commissioning conducive
Trouble Shooting:
1.After energizing the solenoid valve does not work:
Check the power wiring is bad → Re-connect wiring and connectors Check the power supply voltage in the range of ± work → To adjust the range of the normal position Coils are sealing off → Re-welded Coil shorted → Replace the coil Working pressure difference is not appropriate → Adjust the pressure differential/Replace solenoid valve The fluid temperature is too high → Replace solenoid valve Have impurities to make electromagnetic valve of the main valve core and the moving core card to death → Cleaning,such as sealing damage the seal and install the filter should be changed Liquid viscosity is too large,the frequency is too high and had come to life → Replacement product
2.Solenoid valve can not be closed:
The main valve core or moving iron core of seal is damaged → Replace the seal The fluid temperature, viscosity is too high → Replacement of the solenoid valve Are valve core production impurities into the solenoid valve or moving iron core → cleaning Spring life have to or deformation → change Orifice balance hole plug → In a timely manner to clean Working frequency is too high or have to life → Reelection products or product updates
3.Other cases:
Internal leakage → Check whether the seal is damaged, the spring is bad assembly External leakage → Joint looseness or seal has been bad → Screws or replace the seal Electricity from time to tome noise → The head of the fasteners loose,tighten
Package includes:
1 x Solenoid Air Valve 5port 2position
Also Purchased
Recently viewed
Free delivery
Providing Free Delivery Across India
Satisfied or refunded
Don't Like It ? No Worries , We will take it Back.
Top-notch support
Any Queries, Contact us Anytime at Support@shop2india.com