{"product_id":"home-gas-leak-detector-alarm-system-automatic-manipulator-shut-off-valve-device_1605621","title":"Home Gas Leak Detector Alarm System Automatic Manipulator Shut Off Valve Device","description":"\u003cdiv\u003e\n\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMaterial: ABS+Iron\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eColor: White + Black\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePlug: China National Standard Plug(We will be based on your country to send the corresponding adapter plug)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eAlarm Specification:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eVoltage: AC 220V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eStatic power consumption of the whole machine: \u0026lt;2W\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen alarming: \u0026lt;3w\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAlarm concentration: liquefied gas (0.1%~0.5%); natural gas (0.1%~1%); city gas (H2){0.1%~0.5% }\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eGas response recovery time: ≤30S\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking environment: humidity ≤97%RH; temperature: 0°C~60°C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eExecutive standard: CJ3057-1996\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eAlarm Wiring Method:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e+: Connect the positive pole of the power supply (red line)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e-: Connect the negative pole of the power supply (black line)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e--: Networking public (yellow line)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eNC: Normally closed end (white line)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eNO: Normally open (blue line)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eAPPLY:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. Power light: Green light → Flashing: Preheating; always on: Working status\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. Alarm light: Red light → Flashing: alarm; off: Alarm stopping\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. Fault light: yellow light → fault state or when the test button is pressed, it lights up, there is no yellow light, when the fault occurs, the red\/green lights flash alternately\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. Turn on the power, after the green light flashes for 3-5 minutes, the alarm enters the normal working state, or press the test button, the alarm directly enters the working state. When the detected gas reaches the alarm point, the red light starts to flash. After 3 seconds, the alarm device starts to alarm, the red light flashes, the buzzer sounds \"B, B, B....\", press the button again to stop the sound (mute function), The alarm stops when the concentration of the detected gas drops below the alarm point\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e5. After pressing the test button for 3 seconds, the alarm can be simulated, the red light flashes, and the buzzer sounds \"B, B, B...\"\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e6. If the function of the exhaust fan is added, when the detector alarms, the exhaust fan will be activated to automatically eliminate harmful gases.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e7. If a manipulator or solenoid valve function is added, when the detector alarms, the connected manipulator or solenoid valve will automatically close the gas valve, thereby cutting off the harmful air source.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e8. If the networking function is added, when the detector alarms, the management center or control center receives the normally open or normally closed (NO, NC) signal at the same time. For if the wireless function is added, the alarm host will receive the wireless signal.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eManipulator Valve Specification:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking environment: Temperature: -25°C ~ +85°C; Humidity: \u0026lt;95%\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRated voltage: DC 12V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking voltage: DC 8V-16V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRated current: 100mA\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking current: 20mA~300mA\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eRated power: 1.2W\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking power: 0.24W~ 3.6W\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eValve pressure: 1.6MPa\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eValve specifications: 1\/2inch\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAutomatic valve closing time: 6~20 seconds\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eElectric valve opening time: 6~20 seconds\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInsulation resistance: \u0026gt;20MΩ\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWithstand voltage: DC 600V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAnti-radio interference\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWith automatic, manual transfer clutch\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eScope of application:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. Used for automatic control, electric and manual switch of gas pipeline ball valve\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. With gas cylinder special ball valve, it can be used for automatic control of bottled gas\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. It can be connected with various gas alarms.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. Applicable to automatic control of other gas or fluid valves.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage included:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x Alarm\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x Manipulator Valve\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x Screw\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003e1 x Expansion tube\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eDetails Pictures:\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":33829235818634,"sku":"U2I-BG-1605621","price":7527.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/ff10d639-7946-4918-9a9c-fc3c57f051f0.jpg?v=1588643007","url":"https:\/\/shop2india.com\/products\/home-gas-leak-detector-alarm-system-automatic-manipulator-shut-off-valve-device_1605621","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}