{"product_id":"k24-1inch-digital-turbine-diesel-fuel-flow-meter-guage-counter-for-chemicals-water_1139140","title":"K24 1inch Digital Turbine Diesel Fuel Flow Meter Guage Counter for Chemicals Water","description":"\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-The K24 meter feature with complete function of flow meter.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-Simple structure, easy to operate and replace internal components.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e-Apply for oil industry, chemicals, medicine, food industry and commercial.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eProduct Name: Flow Meter\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eModel: K24\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMaterial: Plastic Structure + Rubber Case\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eColor: White + Blue\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eSizes: About 10 x 7 x 5.5cm(L x W x H)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eImport-Export: 1''\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eRepeatability:± 0.5%\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMeasurement accuracy: ± 1%\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eMaximum working pressure: 0.6MPa\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating voltage: 2.3-3.3V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStandby time: 2 year\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eFlow range: 10-120L\/Min\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eSingle count: 0.00 - 999.9\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eTotal cumulative count: 0.00 - 999999.9\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eError Coefficient: 0.1000-9.9999\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eUnit of measurement: L \/ Gal \/ Pts \/ Qts\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eOperating temperature: -10 ° C to 35 ° C\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eBattery Specifications: LR1N x 2 (AAA Size)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eApplication: Diesel, Adbule, Kerosene, Chemicals, Gasoline\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 14px;\"\u003eBattery And Maintenance:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e1. When the battery voltage in the 2.2V to 2.4V, LCD display shows LBat, to remind the user need to replace the battery.(the user is recommended to replace the battery every year, once a year to check the battery electrode).\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e2. If there is corrosion should be promptly removed, a long time without the use of flow meter, the battery should be removed.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 14px;\"\u003eUnit Choose:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 1. Press the CAL + RESET button for 5 seconds in the standby state or the current fill level display to enter the unit conversion settings.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 2. Press the RESET button to select LTR → GAL → PT → QT → LTR, then press the CAL button for 3 seconds to exit the unit conversion setting.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 14px;\"\u003eCalibration Error Coefficient:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 1. Press the MENU button for 3 seconds in the standby state or the current filling amount display status to enter the error coefficient calibration state.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 2. Press the RESET button to change the value of the current flashing digit, from 0 to 9, then to 0, and then press the MENU button to move the cursor to the first digit, press the MENU button, digit shift, (flashing digital displacement).\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003e(Note: The larger the coefficient, the less oil, the smaller the coefficient, the more oil.)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 3. Press the MENU button for 3 seconds to end the calibration of the error coefficient.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 14px;\"\u003eReseting And Reset Total:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 1. Wait for the display to show normal standby display page(with total only displayed)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eStep 2. Press the reset key quickly.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 14px;\"\u003eError Coefficient Adjustment Example:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIf the original coefficient of 1.000, the display shows 100 liters of oil, the actual oil is 100 liters.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 14px;\"\u003eIf you want to add less 2 liters of oil, press the MENU button for 3 seconds, according to the error coefficient calibration in the transferred to 1.020, the future is 98 liters. Want to 96 liters on the tune to 1.040.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size: 14px;\"\u003e1 x Fuel flow meter\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: 16px;\"\u003e\u003cstrong\u003eDetail Pictures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":33931674976394,"sku":"U2I-BG-1139140","price":9359.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/e061588f-47bc-4553-a303-1e890e676aac.jpg?v=1589231389","url":"https:\/\/shop2india.com\/products\/k24-1inch-digital-turbine-diesel-fuel-flow-meter-guage-counter-for-chemicals-water_1139140","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}