{"product_id":"peacefair-ac80-260v-100a-monitoring-multimeter-current-voltage-energy-meter-with-ct-usb_1328023","title":"Peacefair AC80-260V\/100A Monitoring Multimeter Current Voltage Energy Meter With CT\u0026USB","description":"\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eThis is a electric monitoring test multimeter which can be used to test power, energy, voltage and current then displayed on a PC or other terminals. It can store data when power off, and store the accumulated energy data before power off. Designed with one key reset button, you can reset energy data by simply pressing one button. The TTL serial port can communicate, read and set parameters with a variety of terminals through a USB adapter.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e►\u003c\/span\u003eThis is a electric monitoring test multimeter which can be used to test power, energy, voltage and current.\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e►\u003c\/span\u003eThe connection of this module is divided into 2 parts: voltage, current input connection and serial port communication, and you can use different TTL adapters to make it communicate with various terminals.\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e►\u003c\/span\u003eComes with a random color current transformer and a USB adapter for convenient use so you do not have to buy separately.\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e►\u003c\/span\u003eThere is a button for energy data reset, simply press and hold the button for 5 seconds until display flashes and release, then press the button again to finish energy reset.\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e►\u003c\/span\u003eIt has four digital displays and can also displays through PC or other terminals. You can download the software for PC. For other terminals, it need to be programmed by yourself.\u003cbr\u003e \u003cbr\u003e1. Voltage(V), current(A), average power(kW), energy(kWh) measurement.\u003cbr\u003e2. Energy reset by pressing one button.\u003cbr\u003e3. Store data when power off(store the accumulated energy data before power off).\u003cbr\u003e4. LCD display function(display voltage, current, average power, energy).\u003cbr\u003e5. Serial port communication function(TTL serial port can communicate, read and set parameters with a variety of terminals through a USB adapter).\u003cbr\u003e6. Overload alarm.\u003cbr\u003e7. Set power alarm threshold.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e \u003cbr\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eWorking Voltage: 80~260VAC\u003cbr\u003eTest Voltage: 80~260VAC\u003cbr\u003eRated Power: 100A\/22000W\u003cbr\u003eWorking Frequency: 45-65Hz\u003cbr\u003eMeasurement Accuracy: ±1.0%\u003cbr\u003eSize: 118 x 65 x 25mm \/ 4.64 x 2.56 x 0.98\"\u003cbr\u003e \u003cbr\u003eDisplay Format:\u003cbr\u003e1. Power Test Range: 0~22kW\u003cbr\u003e0 ~ 10kW, the display format is 0.000 ~ 9.999\u003cbr\u003e10 ~ 22kW, the display format is 10.00 ~ 22.00\u003cbr\u003e2. Energy Test Range: 0~9999kWh\u003cbr\u003e0 ~ 10kWh, the display format is 0.000 ~ 9.999\u003cbr\u003e10 ~ 100kWh, the display format is 10.00 ~ 99.99\u003cbr\u003e100 ~ 1000kWh, the display format is 100.0 ~ 999.9\u003cbr\u003e1000 ~ 9999kWh and above, the display format is 1000 ~ 9999\u003cbr\u003e3. Voltage Test Range: 80~260VAC\u003cbr\u003eDisplay Format is 110.0 ~ 220.0\u003cbr\u003e4. Current Test Range: 0~100A\u003cbr\u003eDisplay Format is 00.00 ~ 99.99\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eSerial Port Communication\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e \u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eThis multimeter is design with TTL serial port data communication interface, you can read and set the relevant parameters via serial port. If it need to communicate with a device which has USB or RS232 (such as computer), a TTL adapter is required. In the below table are the communication protocols of this module:\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" style=\"width:665px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eFunction \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eHead \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eData1- Data5 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eSum \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eVoltage \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 00 (Computer sends a command to read the voltage value) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e1A \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e00 E6 02 00 00 (Meter reply the voltage value is 230.2V) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e88 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eCurrent \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB1 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 00 (Computer sends a command to read the current value) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e1B \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA1 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e00 11 20 00 00 (Meter reply the current value is 17.32A) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eD2 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eAverage Power \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB2 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 00 (Computer sends a command to read the average power value) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e1C \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA2 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e08 98 00 00 00 (Meter reply the average power value is 2200w) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e42 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eRead Energy \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB3 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 00 (Computer sends a command to read the energy value) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e1D \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA3 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e01 86 9f 00 00 (Meter reply the energy value is 99999wh) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC9 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eSet Module Address \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB4 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 00 (Computer sends a command to set the address, the address is 192.168.1.1) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e1E \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA4 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e00 00 00 00 00 (Meter reply the address was successfully set) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA4 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan style=\"font-size:14px;\"\u003eSet Power Alarm Threshold \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eB5 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eC0 A8 01 01 14 (computer sends a command to set a power alarm threshold) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e33 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA5 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003e00 00 00 00 00 (Meter reply the power alarm threshold  was successfully set) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:14px;\"\u003eA5 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eIllustration of Communication Protocol:\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e1. Set the communication address: 192.168.1.1\u003cbr\u003eSend Command: B4 C0 A8 01 01 00 1E\u003cbr\u003eReply Data: A4 00 00 00 00 00 A4\u003cbr\u003e \u003cbr\u003eNote: The above example illustrate that setting the communication address as 192.168.1.1 (the user can set their own address based on their preferences and needs), sending command and automatic replying data are as shown above, the data are expressed in hexadecimal; the last byte of the sending and replying data are 1E and A4, which is cumulative sum. In sending commands: B4 + C0 + A8 + 01 + 01 + 00 = 21E (hexadecimal), the cumulative sum data is 21E, take the last two bytes 1E as the cumulative sum data in sending commands; in reply data: A4 + 00 + 00 + 00 + 00 + 00 = A4 (hexadecimal), the cumulative sum data is A4, which is the cumulative sum data in reply.\u003cbr\u003e \u003cbr\u003e2. Set the power alarm threshold: 20 KW\u003cbr\u003eSend command: B5 C0 A8 01 01 14 33\u003cbr\u003eReply data: A5 00 00 00 00 00 A5\u003cbr\u003e \u003cbr\u003eNote: 14 in the sending command is the alarm threshold value (14 is a hexadecimal data representation, which converted to decimal is 20). The power alarm value of this module is based on KW units, and the minimum alarm value is 1KW, the maximum value is 22KW.\u003cbr\u003e \u003cbr\u003e3. Read the voltage\u003cbr\u003eSend command: B0 C0 A8 01 01 00 1A\u003cbr\u003eReply data: A0 00 E6 02 00 00 88\u003cbr\u003e \u003cbr\u003eNote: Reply voltage data is D1D2D3 = 00 E6 02, 00 E6 represent the integer-bit of the voltage, 02 represent the decimal of the voltage, the decimal is one digit, converts 00 E6 to decimal is 230; converts 02 to decimal is 2, so the current voltage value is 230.2V.\u003cbr\u003e \u003cbr\u003e4. Read the current\u003cbr\u003eSend command: B1 C0 A8 01 01 00 1B\u003cbr\u003eReply data: A1 00 11 20 00 00 D2\u003cbr\u003e \u003cbr\u003eNote: Reply current data is D2D3 = 11 20, 11 represent the integer-bit of the current, 20 represent the decimal of the current, the current decimal is two digits, converts 11 to decimal is 17; converts 20 to decimal is 32, so the current value is 17.32 A.\u003cbr\u003e \u003cbr\u003e5. Read the power\u003cbr\u003eSend command: B2 C0 A8 01 01 00 1C\u003cbr\u003eReply data: A2 08 98 00 00 00 42\u003cbr\u003e \u003cbr\u003eNote: Reply power data is D1D2 = 08 98, converts 08 98 to decimal is 2200, so the current voltage value is 2200W.\u003cbr\u003e \u003cbr\u003e6. Read the energy\u003cbr\u003eSend command: B3 C0 A8 01 01 00 1D\u003cbr\u003eReply data: A3 01 86 9F 00 00 C9\u003cbr\u003e \u003cbr\u003eNote: Reply energy data is D1D2D3 = 01 86 9F, converts 01 86 9F to decimal is 99999, so the accumulated energy is 99999Wh.\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eIllustration of Communication\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e1. Connect hardware according to the wiring diagram below.\u003cbr\u003e \u003cbr\u003e2. After wiring, please choose the communication port, this module's host computer software support communication port: COM2COM3COM4, you can check through device manager, if it is not the above communication port, you should amend it.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px;\"\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e1.This is an indoor module and can not be used outdoors.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e2.Load can be over rated power.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e3.Wiring can not be wrong.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage includes:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x Multimeter\u003cbr\u003e1 x USB Adapter\u003cbr\u003e1 x Current Transformer\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e \u003cbr\u003eDetails pictures:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":34761025618088,"sku":"U2I-BG-1328023","price":6132.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/5d1c9f07-bc5f-442f-8c79-421b8c4a54d6.jpg?v=1592422477","url":"https:\/\/shop2india.com\/products\/peacefair-ac80-260v-100a-monitoring-multimeter-current-voltage-energy-meter-with-ct-usb_1328023","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}