{"product_id":"riden-100v-20a-7in1-oled-multifunction-tester-voltage-current-time-temperature-capacity-voltmeter-ammeter-electrical-parameter-meter_1120289","title":"RIDEN 100V\/20A 7in1 OLED Multifunction Tester Voltage Current Time Temperature Capacity Voltmeter Ammeter Electrical Parameter Meter","description":"\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eVoltage measurement range: DC00.0-99.9V                     Current measurement range: DC00.0-20.0A\u003cbr\u003eTime measurement range: 0-99h59min                            Power measurement range: 0-999.9-2000 W\u003cbr\u003eTemperature measurement range: -15 °c ~60°c                Capacity accumulation range: 0-999.99-9999.9 Ah\u003cbr\u003eEnergy accumulation range: 0-99999Wh-9999KWh           Voltage measurement accuracy: ± (0.5% + 2digits)\u003cbr\u003eCurrent measurement accuracy: ± (1% + 2 digits)             Product weight: 33g  \u003cbr\u003eProduct size: 48mm*29mm*22mm (L*W*H)\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eDisplay Interface Instruction\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003e: \u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e①Run time\u003cbr\u003e②Power display\u003cbr\u003e③Data set\u003cbr\u003e④Temperature display\u003cbr\u003e⑤Capacity display\u003cbr\u003e⑥Voltage display\u003cbr\u003e⑦Current display\u003cbr\u003e⑧Energy display\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eButton Function Instruction:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThis tester has 0 and 1 two data groups; and data groups are switched by pressing the key.\u003cbr\u003eWhen data group is the 1 group, the current capacity and energy will be stored after power off.\u003cbr\u003eAnd the stored values will be accumulated after power on. When the data group is the 0 group,\u003cbr\u003ethe current capacity and energy will be stored after power off; when power on next time,\u003cbr\u003ethe stored capacity and energy are blinking displayed. But when the new capacity is up to 0.01Ah,\u003cbr\u003ethe stored capacity and energy will be covered, and the values will start over. At the two data groups,\u003cbr\u003ethe accumulated values can be cleared to zero by keeping pressing the key.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eZero calibration operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eWith the aging of components and influence of ambient temp, there might be tiny error for the current reading,\u003cbr\u003eespecially when measuring low current. To calibrate it: 1, power off the meter.2, disconnect the load.\u003cbr\u003e3 press and hold the front button .4, power on the meter.5, release the button when you see “AAA” on the screen.\u003cbr\u003eDone\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eThe Wiring Diagram Instruction:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e①Red thin line\u003cbr\u003e②Black thin line\u003cbr\u003e③Yellow thin line\u003cbr\u003e④Red thick line\u003cbr\u003e⑤Black thick line\u003cbr\u003e⑥Load\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"color:#ff0000;\"\u003ePlease ensure proper wiring in strict accordance with the wiring diagram.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUsing Isolated Power Supply to power the meter \u003c\/strong\u003e\u003cbr\u003eThe two power supplies must be isolated and don’t have any connections between them.\u003cbr\u003eThe voltage of the isolated power supply must be less 60V\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUsing system to power the meter\u003c\/strong\u003e \u003cbr\u003eThe black thin wire connects nothing and you should use insulator wrap it to avoid short circuit.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUsing DC-DC converter to power the meter\u003c\/strong\u003e\u003cbr\u003eThe black thin wire connects nothing and you should use insulator wrap it to avoid short circuit.\u003cbr\u003eThe DC-DC converter must be common cathode structure.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage included:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x 100V\/20A 7in1 OLED Multifunction Tester\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e,,,","brand":"Banggood","offers":[{"title":"Default Title","offer_id":34938317439144,"sku":"U2I-BG-1120289","price":2351.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/7c9a55d1-fbe3-4f7f-854d-891ca4c979ca.jpg?v=1593433381","url":"https:\/\/shop2india.com\/products\/riden-100v-20a-7in1-oled-multifunction-tester-voltage-current-time-temperature-capacity-voltmeter-ammeter-electrical-parameter-meter_1120289","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}