{"product_id":"riden-dph5005-converter-constant-voltage-current-programmable-digital-power-supply-module_1230368","title":"RIDEN DPH5005 Converter Constant Voltage Current Programmable Digital Power Supply Module","description":"\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eInformation:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eDigital Control Buck-Boost Supply Power Module put the collection of analog integration and digital control functions in one. Its adjustable output voltage range is 0-50.00V, step by 0.01V. Its adjustable output current range is 0-5.000A, step by 0.001A. This module has power-down stored function and can store 10 groups preset value. And it also has the function of extracting quickly two groups stored value. Compared with the traditional analog power supply, it is more convenient to quickly extract the voltage or current required. LCD display on the module has the function of digital voltmeter and ammeter. You can view the preset voltage, input voltage, output voltage, the preset current, output current, output power, etc. On the output state remind area, you can see that output opens or not, the state of constant voltage and constant current, output is normal or not, the key is locked or not, and the current data groups that is being used. On the setting data interface, you can adjust overvoltage value, overcurrent value, over-power value, data group and LCD brightness. This module adopts buck-boost structure; when input voltage is lower than, equal to or higher than output voltage, output voltage is still stable and changeless. This feature has wide range of application.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eNotice:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1.Before buying this product, please download the upper computer software and test, if it fits your computer , you can buy\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. the upper computer only support For Win7 and above\u003c\/span\u003e\u003c\/div\u003e\u003cspan style=\"font-size:14px;\"\u003ePC software \u0026amp; manual: \u003ca href=\"http:\/\/files.banggood.com\/2018\/10\/DPH5005-PC-Software-V1.5.zip\" target=\"_blank\"\u003e\u003cspan style=\"color:#ff0000;\"\u003eDownload here!\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"http:\/\/files.banggood.com\/2018\/10\/DPH5005-CE.jpg\" target=\"_blank\"\u003eCE: http:\/\/files.banggood.com\/2018\/10\/DPH5005-CE.jpg\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eTechnical parameters:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eInput voltage range:  6-50V                                            Output voltage range:  0V-50.00V\u003cbr\u003eOutput current: 0-5.000A                                                Output power range: 0-250W \u003cbr\u003eMax allowable input current: 10A                                    Output ripple: about 100mVpp\u003cbr\u003eProduct Weight: about 267g                                           Display module size: 79*43*38(mm) (L*W*H)\u003cbr\u003eOpen size:  76mm*39mm                                                Power module size: 93*72*42(mm) (L*W*H) \u003cbr\u003eLength of connecting line: 200mm                                  Fixed hole center distance: 86mm, 64mm\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage included:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color:#ff0000;\"\u003eType A: DPH5005 No Communication Version\u003cbr\u003eType B: DPH5005 USB Communication Version\u003cbr\u003eType C: DPH5005 Communication Version USB Board+bluetooth Board\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003eOutput voltage program and read back resolution: 0.01V               \u003cbr\u003eOutput current program and read back resolution: 0.001A \u003cbr\u003eOutput Voltage program and read back accuracy: ± (0.5% + 2 digits)       \u003cbr\u003eOutput Current program and read back accuracy: ± (0.5% + 3 digits)\u003cbr\u003eTemperature of the application environment: -10°c ~45°c\u003cbr\u003e \u003cbr\u003e\u003cspan style=\"color:#ff0000;\"\u003eNOTE: 1.If you want to ensure output at full load, you must make sure that input is higher than 28V and 280W;\u003cbr\u003epay attention to heat elimination at full load.\u003cbr\u003e2. Connection between display part and power part should be according to the corresponding words.\u003cbr\u003eOtherwise it will not work by wrong connection \u003c\/span\u003e\u003cem\u003e \u003c\/em\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eConnection description:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIN+: Input positive                       IN-: Input negative:\u003cbr\u003eOUT+: Output positive:              OUT-: Output negative    \u003cbr\u003eNote: Input voltage range is DC 6-50V and 50V is the limit voltage; please leave a room to use. Or else it will be burnt.\u003cbr\u003eThe input must be DC power supply, not AC 220V, or else it will be burnt too. Though this module has reverse connection\u003cbr\u003eprotection and output short circuit protection, you can muse be in strict accordance with connection description to connect.\u003cbr\u003eIf you connect the supply power with output, the module will be burnt.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePanel description:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e1-Voltage setting\/Page up to choose\/Shortcut extract M1 data group\u003cbr\u003e2-Data setting\/ Extract value of the specified data group\/Store value into the specified data group\u003cbr\u003e3-Current setting\/Page Down to choose\/Shortcut extract M2 data group\u003cbr\u003e4-1.44 inch color LCD screen\u003cbr\u003e5-Coding potentiometer\/Data adjustment\/Lock all buttons\u003cbr\u003e6-Open or close output\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eDisplay interface description:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e7-The preset value of output voltage\u003cbr\u003e8- The actual value of output voltage\u003cbr\u003e9-The actual value of output current\u003cbr\u003e10-The actual value of output power\u003cbr\u003e11-The actual value of input voltage\u003cbr\u003e12-The preset value of output current\u003cbr\u003e13-Key lock or unlock prompt\u003cbr\u003e14-Output normal or not prompt\u003cbr\u003e15-Constant voltage and constant current status prompt  \u003cbr\u003e16-Data set prompt\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e17-Open or close output prompt\u003cbr\u003e18-Preset output voltage\u003cbr\u003e19-Preset output current\u003cbr\u003e20-Preset over- voltage\u003cbr\u003e21-Preset over-current\u003cbr\u003e22-Preset over-power\u003cbr\u003e23-Preset screen brightness\u003cbr\u003e24-Preset data set\u003cbr\u003e25-The actual value of output voltage and output current\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eOperating instructions:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eWhen connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lock icon, abnormal output status icon, constant voltage and constant current icon, data set tip icon and opening or closing output icon.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSet the output voltage and output current on the main interface.\u003c\/strong\u003e\u003cbr\u003ePress V\/↑key shortly, you can enter into voltage setting status. Then press the coding potentiometer, and then enter to adjust the numerical value. Press coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clockwise rotation to increase the numerical value; Turn by counterclockwise to decrease the numerical value. If you want to exit adjusting the numerical value, press shortly V\/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too.  You can press A\/↓to set the output current by the same way.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSet the data on the data setting interface.\u003c\/strong\u003e\u003cbr\u003eOn the main interface, you can press SET key shortly to enter into data setting interface. On the data setting interface, press shortly V\/↑or A\/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface .\u003cbr\u003e\u003cstrong\u003eSet the protection value. \u003c\/strong\u003e\u003cbr\u003ePage up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed ; and there is a prompt on right of screen . And then press shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, press shortly SET key.\u003cbr\u003e\u003cstrong\u003eAdjust the brightness of screen. \u003c\/strong\u003e\u003cbr\u003ePage up or page down to B-LED, and then press shortly the coding potentiometer to enter into the status of adjusting the brightness of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, press shortly SET key. There are six brightness levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.  \u003cbr\u003e\u003cstrong\u003eData setting and store the specified data group. \u003c\/strong\u003e\u003cbr\u003ePage up or page down to M-PRE, and then press shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then press the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, press shortly SET key. Then press shortly V\/↑or A\/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep pressing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can press shortly SET key back to the main interface.\u003cbr\u003e\u003cstrong\u003eSet default boot open or close output\u003c\/strong\u003e\u003cbr\u003ePage up or page down to S-INI, and then press shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px;\"\u003eFunction description:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOpen or close the output\u003c\/strong\u003e.\u003cbr\u003eYou can press ON\/OFF key to open or close the output on any interface.\u003cbr\u003e\u003cstrong\u003eLock the button to avoid wrong operation.\u003c\/strong\u003e\u003cbr\u003eOn the any interface, you can keep pressing coding potentiometer more than 2s, all buttons are locked. You can see the key lock icon on the right of screen. If you want to unlock all buttons, keep pressing coding potentiometer more than 2s, all buttons are unlocked. The key unlock icon will be displayed on the right of screen.\u003cbr\u003e\u003cstrong\u003eM0-M9 ten groups data group\u003c\/strong\u003e\u003cbr\u003eM0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.\u003cbr\u003e\u003cstrong\u003eExtract Shortcut storage data group M1 or M2.\u003c\/strong\u003e\u003cbr\u003eOn the main interface, keep pressing V\/↑or A\/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quickly. In the same time the corresponding data group number will displayed on the right of the screen.\u003cbr\u003e\u003cstrong\u003eExtract the specified data group.\u003c\/strong\u003e\u003cbr\u003eOn the main interface, keep pressing SET key more than 2s, the sequence number of data group will be displayed on the right of the screen, you can turn coding potentiometer to choose data group you need. And then press shortly SET key, you can extract the specified data group you need.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Banggood","offers":[{"title":"A","offer_id":34938369015976,"sku":"U2I-BG-1230368","price":9879.0,"currency_code":"INR","in_stock":true},{"title":"B","offer_id":34938369114280,"sku":"U2I-BG-1230368","price":9889.0,"currency_code":"INR","in_stock":true},{"title":"C","offer_id":34938369212584,"sku":"U2I-BG-1230368","price":9899.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/b99126f1-93eb-4b37-a565-688d64cb1c25.jpg?v=1593433537","url":"https:\/\/shop2india.com\/products\/riden-dph5005-converter-constant-voltage-current-programmable-digital-power-supply-module_1230368","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}