{"product_id":"xy-cd60-solar-battery-charger-controller-12v-24v-48v-charging-discharge-control-module-voltage-current-protector-board_1572343","title":"XY-CD60 Solar Battery Charger Controller 12V 24V 48V Charging Discharge Control Module Voltage Current Protector Board","description":"\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e- Made of high quality material, sturdy, durable and practical to use.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e- Great for fixing overload and low voltage, protects the battery from undervoltage, protects the battery from overcharging, and protects the load control, prolong battery life.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e- When the battery voltage is insufficient, disconnect the load and connect the charger. When the battery voltage is too high, disconnect the charger and connect the load.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e- Adjustable parameters and LCD screen, show you the parameters clearly, easy to use.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e- With a control voltage 6-60V, it is suitable for batteries, lithium batteries, etc.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eMaterial: Plastic\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eModel: XY-CD60\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSize: app.79 x 43 x 38mm\/3.11 x 1.69 x 1.50in\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eControl voltage: 6-60V\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eModes: Charging Mode; Discharging Mode\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eColor: As picture shown\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eUsage:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eCharging Mode IN:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eBy setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage UP, the relay disconnects to complete an automatic charging; when the relay turns on, IN flickers, indicating that it is charging.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eDischarging Mode OUT:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eBy setting the upper limit voltage UP and the lower limit voltage dn; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage dn, the relay turns off and completes an automatic discharging function; when the relay turns on, the OUT flickers, indicating that it is discharging.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eTip:\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003eThis product is a simple voltage controller. It can turn on and off the output by relay. It only plays the role of switching, and can not change the voltage.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e\n\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFunctional Instruction:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. Calculation of Voltage Percentage: Battery Voltage\/(Upper Voltage-Lower Voltage)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. Key function:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eUP: Short press display % and time, long press 5 seconds to switch mode; charging mode: IN, discharge mode: OUT.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eSET: Short press to check the parameters currently set; long press to enter the parameter setting interface, set UP: voltage upper limit, dn: voltage lower limit, OP: turn-on time, dOP: delay turn-on time (0-999 seconds), FOP: forced turn-on time (0-10 seconds) in discharge mode.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eDOWN: Turn off\/on electric relay enable (emergency stop function) turn off, LCD display OFF, relay disconnect: long press to set the status of LCD backlight, L-P: OFF backlight constant brightness, ON: Backlight automatically extinguishes after 5-10 minutes; after extinguishing, press any keys to wake up.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. Parameter Settings\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ea. Enter the parameter setting interface by pressing the SET;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eb. After entering the parameter setting interface, switch the setting parameters by short pressing SET;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ec. After choosing parameters, it can be set by UP\/DOWN key, supporting short press or long press.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ed. If you want to set other parameters, repeat steps b and c;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ee.  After all parameters are set, long press SET to exit and save;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.1 Charging\/Discharging Time Control Function\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1) When the time parameter OP is non-zero, start charging\/discharging time control.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2) When the relay turns on a charge\/discharge, the countdown begins; when it is completed, the relay is automatically disconnected to complete a charge\/discharge process; if the time is completed, under the charging mode, the detection voltage is less than the lower limit voltage dn or in the discharge mode, the detection voltage is larger than the upper limit voltage UP, and the charging time control function is automatically turned off and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3) When the charging\/discharging time control is not turned on, the product will record a complete time. When entering the time display interface, flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on).\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.2 Automatic parameter detection:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eWhen the parameters are set and exit, if the lower voltage limit DN is larger than the upper voltage up, the system will flicker to display \"ERR\" as a reminder.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.3 Delayed turn-on function (0-999 seconds):\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eCompletion of a charge\/discharge, the interval between re-opening;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3.4 Discharge Conduction Forced Start Time (0-10S):\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAfter satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eAnalysis of Common Faults:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eQuestion 1: How many V levels are suitable for use? How many V voltage does this module fit?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eAnswer 1: This model is suitable for use in the range of minimum 6V, maximum 60V voltage and maximum expenditure level 48V, because 48V battery is full of electricity at about 60V, and then burns at a higher level. If your battery is higher than 48V, please choose another one.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eQ2: The relay clicks after power-on! Does the light flicker?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eA2: This is because your charging current is too large or the battery capacity is too small. Once the battery is powered up, it immediately reaches the upper voltage limit. The relay is disconnected. After disconnection, the voltage quickly drops to the lower voltage limit and starts charging again. At this time, you need to reduce the charging current. Usually, the charging current is 10% of the battery capacity. From 1 to 1.5, the charging current of 20AH batteries is generally about 2-3A. Note that high current charging can cause battery heating, accelerated aging, bulging and even explosion!\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eQ3: What control method? Can it be recharged automatically? Can you fill it while you use it? Can we limit the current?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eA3: This is voltage control, such as setting the lower limit of voltage 12.0V, the upper limit of voltage 14.5V, when the voltage is charged to 14.5V, the power is cut off, the voltage is lowered to 12.0V and the relay is closed to start charging; while charging, the voltage control mode can only switch on and off, not limit the current, the charging current depends entirely on your charger!\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eQ4: Can I charge a 24V battery with 12V input, or can I charge a 12V battery with 48V input?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eA4: This is a simple voltage controller. It only plays a switching role. It can't change the voltage to charge the battery. So what kind of charger should you prepare to charge the battery? Necessary!\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x XY-CD60 Solar Battery Charger Controller 12V 24V 48V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":35595009097896,"sku":"U2I-BG-1572343","price":2685.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/4cd912a7-1350-441a-92c3-c441168041fe.jpg?v=1596742658","url":"https:\/\/shop2india.com\/products\/xy-cd60-solar-battery-charger-controller-12v-24v-48v-charging-discharge-control-module-voltage-current-protector-board_1572343","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}