{"product_id":"yyw-2-0-1024-temperature-sensor-temperature-control-relay-detection-high-temperature-serial-output-with-k-type-thermocouple-30a_1624679","title":"YYW-2 0-1024 Temperature Sensor Temperature Control Relay Detection High Temperature Serial Output with K Type Thermocouple 30A","description":"\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e-Add ms level delay time to prevent output oscillation and cause damage to the entire circuit.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e-Can turn off the display for a long time, reducing power consumption\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e-Synchronous data acquisition serial output\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eInput supply voltage: DC 7 ~ 30V universal\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eOutput controllable power: DC \/ AC within 30A\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eProbe model: K-type thermocouple Wire length 0.5M\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eScrew head specifications: M6\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eResolution: 1 degree\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFunction Description:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e(A and B are the values ​​we can set by ourselves)\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--1: When the measurement is lower than the temperature value A, the relay is activated, and when the temperature is higher than the temperature value B, the relay is disconnected;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--2: When the measurement is higher than the temperature value B, the relay is activated, and when the temperature is lower than the temperature value A, the relay is disconnected;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--3: When the measured temperature is between A and B, the relay is turned off, and the relay is closed in other cases;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--4: When the measured temperature is between A and B, the relay is closed, otherwise the relay is opened;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--5: When the measured temperature is higher than the temperature value B, the relay is turned on, and the temperature is lower than the A relay is turned off;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--6: When the measured temperature is higher than the temperature value A, the relay is activated; it is always activated; until the power is cut off manually\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eP--7: When the measured temperature is equal to A each time, the relay outputs a jog signal\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cbr\u003e\u003cstrong style=\"font-size: 16px;\"\u003eSetting instructions:\u003c\/strong\u003e\n\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePower-on indicates that the measured temperature enters the standby state;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePress K1 for the first time (it takes more than 1 second to be effective to prevent false triggering), the screen flashes: P --1: K2 plus mode, K3 minus mode\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePress K1 a second time, the screen flashes: A025 means: A = 25 degrees: K2 and K3 adjust A\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePress K1 a third time, the screen flashes: B035 indicates: B = 35 degrees: K2 and K3 adjust B\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePress K1 for the fourth time, the display shows the measured real-time temperature indicating that it has entered the standby state;\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003ePress K4 in standby mode to permanently turn off \/ on the display and switch the low power consumption mode.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x YYW-2 0-1024 ℃ Temperature Sensor Module\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1 x K Type Thermocouple Sensor Cable\u003c\/span\u003e\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Banggood","offers":[{"title":"Default Title","offer_id":35616184041640,"sku":"U2I-BG-1624679","price":3774.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/1588\/1354\/products\/1ad448b4-56fd-4a73-9122-554e69c9522b.jpg?v=1596830584","url":"https:\/\/shop2india.com\/products\/yyw-2-0-1024-temperature-sensor-temperature-control-relay-detection-high-temperature-serial-output-with-k-type-thermocouple-30a_1624679","provider":"SHOP2INDIA GATEWAY","version":"1.0","type":"link"}