Specifiations:
Input voltage: 12V/24V/220V
Working current: 0.15A
Relay power: 1200W
Timing optional: seconds / minute / hour
Display: 0.1 second
Features:
This timer is accurate to 1-999 sec/min/hr. First, it can control the hours and seconds in a single time, and can be easily switched in three ways; second, to achieve linkage control; third, independent timing control; fourth, can cycle timing...
Instructions:
1. Turn on the power, and display the delay time on both the left and right sides.
2. Press the “SET” button once to control the working time of relay No. 1 by adding and subtracting keys.
3. Press the “SET” button twice in succession to control the working time of relay No. 2 by the addition and subtraction keys.
4. Press and hold the “SET” button for 10 seconds to enter the project menu.
Numbering |
Function Description |
default |
|
P0 |
Switch seconds/minute/hour |
0 second |
1 minute |
P1 |
Linkage control |
OFF |
ON |
P2 |
Independent timing control |
OFF |
ON |
P3 |
Loop mode |
OFF |
ON |
P4 |
1-999 seconds, the timing of the cycle |
|
|
Note:
1. Restore the factory settings, press and hold the 1 and 5 keys at the same time after power on, and display 8 8 after 5 seconds. The setting is successful.
2. Time is gone, not countdown
3. If the button is re-triggered while working, all timing needs to be restarted.
Package Included:
1 x Multi-function Intermittent Cycle Timer